Three-phase brushless DC Pump DC55E

DC55E
Impeller:Closed Impeller
Max head: 16M
Weight:0.52kg
Rated voltage:12Vdc or 24Vdc
Max flow:2400L/H

Description

一.Product Feature

1Product nameZKSJ DC55E Brushless DC Pump
2Model No.DC55E
3Weight:0.52kg
4Life span:≥30000h 
5Waterproof Grade:IP68
6Color:Black
7EPL:CE,ROSH
8Material of pump shell:PPS+30%GF
9Noise class:≤35dB
10Leakproofness:1MPa(10kg)
11Insulation grade:H Grade(180°)
12Working principle:Centrifugal pump
13Application  Cooling circulation pump, booster pump, pumping pump.

二.Range

1Liquid TypeOil, water, and other liquids
2Liquid Temperature-30℃-100℃(with built-in driver for non-submersible;with external driver for submersible)
3Speed regulation method(optional):l PWM Speed:amplitude 5V 50-800HZ  Can be customizedl 0-5V Speedl Potentiometer speed regulation:The resistance range 4.7K~20K
4PowerDC Power Supply,Solar Panel,Battery

三.Basic parameters (parameters can be customized)

1Product model:DC55E-12120PWM;
DC55E-12120VR;
DC55E-12120VSDC55E-12120S
DC55E-24120PWM;
DC55E-24120VR;
DC55E-24120VSDC55E-24120S
DC55E-24160PWM;
DC55E-24160VR;
DC55E-24160VSDC55E-24160S
DC55E-36160PWM;
DC55E-36160VR;
DC55E-36160S
PWM: PWM(50-800HZ/ 5V)VR: Potentiometer speed regulationVS: 0~5V Speed regulation by analog voltage signalS: Fixed rotational speed
2Rated Voltage:12V DC24V DC24V DC36V DC
3Working voltage:5-12V12-30V12-30V5-40VWithin this range, the pump can work normally
4Rated current:3.5A(4.5A)1.4A(2.2A)2.7A(3.3A)1.8A(2.2A)Closed outlet current (open pumping current)
5power:42W(54W)42W(54W)65W(80W)65W(80W)Closed outlet power (open pumping power)
6Max. Flow rate:2000L/H2000L/H2300L/H2400L/HFlow rate without connecting pipe
7Max. Head:12M12M16M16MStatic head
8Min. Input power supply:12V-5A24V-4A24V-4A36V-3A

四.Additional function instructions

1K-jam protectionWhen the impurity enters the rotor chamber, the rotor stops running, and the pump stops running as well.
2Dry run protectionThe pump will stop working when no enough water inside pump.
3Overloading protectionWhen the voltage is unstable or exceeds the rated power, the pump will stop working.
4Power reverse connectionWrong connection of the power supply(positive and negative), the water pump will stop running, and then re-connected, can work normally.

Dimensions of pump