BLDC Pump DC80D

Product information:

  • Voltage (DC): 24V
  • Current range: 0.5~6.6A
  • Max lift: 8m
  • Max flow: 105L/MIN
  • Inlet/ Outlet Dimension: 38mm/38mm

 

DC80D Series (Three-phase)

Product Appearance 

图片关键词

 Specifications

NO.

Item

Specs

1

Dimension and weight

144mm*213.8mm*147.3mm;2.1kg

2

External diameter of outlet

38mm

3

External diameter of inlet

38mm

4

Driving mechanism

Brush-less, magnetic isolated design

5

Material of pump shell

ABS,PES/SPS/PPS/PA66+30%GF(Optional)

6

Condition of use

Can continuously work, submersible or land use (not self-priming)

7

Suitable medium

Water, oil, or normal acid/ alkaline liquids

(Test needed for special liquid)

8

Max working temperature

120

Three- phase pump with controller inside for nonsubmersible installation.

Three – phase pump with controller outside for submersible installation

9

Power consumption

80W/120W

10

Rated voltage

12Vdc or 24Vdc

11

Working voltage range

5Vdc ~ 14Vdc(MAX) or 5Vdc ~ 26Vdc(MAX)

12

Max load current

6.6A/5A

13

Max horizontal flow rate

5300L/H 6300L/H

14

Max static lift

6.5M/8M                                

15

Noise class

<40dB

16

Waterproof class

IP68(suitable for submersible installation)

17

Life span

Can be more than 30,000hrs

18

Power supply

Suitable for solar panel, batteries, adapter or other power module

19

Protection function

Water protection, dry-run protection, stall protection, stuck protection

(functions are optional for customization)

20

Power regulation function

Speed can adjustable by PWM signal, 0~5V analog signal or potentiometer

21

Feature

l  small size with high efficiency,maintenance-free

l  Use ceramics shaft and carbon fiber sleeve

l  Completely water proof (IP68)

l  Brush-less dc control without pollution, long life span

l  OEM and ODM service accept

l  Offer Pump related control system design

Electrical parameters (only for reference)

Model No.

Voltage

Max load current

Max static lift

Max flow rate

Power consumption

V(dc)

A

M

 L/H

w

DC80D-1265S

12

6.6

6.5

5300

80

DC80D-1265A

12

6.6

6.5

5300

80

DC80D2480S

24

5

8

6300

120

DC80D2480A

24

5

8

6300

120

NOTE

l  Information including continuous working time, working temperature and medium is required to be confirmed by professionals; pump cannot work with high temperature or corrosive fluids.

l  When pump is connected into circulation system, load current will be reduced to 70~85% of Max working current (opening outlet current).

l  Head means the Max vertical lifting height of water, the flow is 0L/MIN@max head.

l  The max flow rate means flow rate with no lifting height(horizontal flow rate)

Flow rate-lift Curve

图片关键词

Dimensions of pump

图片关键词


Outlook detail

图片关键词


在线预定

Telephone
Product list
Mall