BLDC Pump DC50M

Product information:

  • Voltage (DC): 24V
  • Current range: 0.15~3.8A
  • Max lift: 13m
  • Max flow: 23L/MIN
  • Inlet/ Outlet Dimension: 1/2"thread 1/2"thread

  DC50M Series(Three-phase)+ 

Product Appearance 

图片关键词

Specifications

NO.

Item

Specs

1

Dimension and weight

92.9mmx107mmx62.9mm;480g

2

External diameter of outlet

1/2” thread(M20)

3

External diameter of inlet

1/2” thread(M20)

4

Driving mechanism

Brush-less, magnetic isolated design

5

Material of pump shell

PA66+30%GF (Optional ABS,PES/SPS/PPS/)

6

Condition of use

Can continuously work, submersible or land use (not self-priming)

7

Suitable medium

Water, oil, or normal acid/ alkaline liquids

8

Max working temperature

100℃(for S/A sub-series)

9

Power consumption

52W~80W(for S/A sub-series)

10

Rated voltage

12Vdc or 24Vdc

11

Working voltage range

5Vdc ~ 14Vdc or 5Vdc ~ 26Vdc

12

Max load current

4.3A(for S/A sub-series)

13

Max horizontal flow rate

22.5L/MIN(for S/A sub-series)

14

Max static lift

13M(for S/A sub-series)                           

15

Noise class

<40dB

16

Waterproof class

IP68(suitable for submersible installation)

17

Life span

>20,000hrsIP68(suitable for submersible installation)

18

Power supply

Suitable solar panel, batteries, adapter or other power source

19

Protection function

dry-run protection, lock protection(customized function)

20

Power regulation function

Speed adjustable by PWM signal, 0~5V analog signal or potentiometer

22

Feature

small size with high efficiency,maintenance-free

Use ceramics shaft and carbon fiber sleeve

Completely water proof (IP68)

Brush-less dc control without pollution, long life span

OEM and ODM service accept

Offer Pump related control system design

Electrical parameters (only for reference)

 

Model No.

Voltage

Max load current

Max static lift

Max flow rate

Power consumption

V(dc)

A

M

L/H

W

DC50M-1290S

12

4.3A

9M

1200L/H

52W

DC50M- 1290A

DC50M 2480S

24

2.2A

8M

1150L/H

55W

DC50M-2480A

DC50M-24130S

24

3.3A

13M

1350L/H

80W

DC50M-24130A

NOTE

l   Information including continuous working time, working temperature and medium is required to be confirmed by  professionals; pump cannot work with high temperature or corrosive fluids.

l  When pump is connected into circulation system, load current will be reduced to 70~85% of Max working current (opening outlet current).

l  Head means the Max vertical lifting height of water, the flow is 0L/MIN@max head.

The max flow rate means flow rate with no lifting height(horizontal flow rate)