BLDC Pump DC50G

Product information:

  • Voltage (DC): 24V
  • Current range: 0.15~3.8A
  • Max lift: 8m
  • Max flow: 40L/MIN
  • Inlet/ Outlet Dimension: 1/2"thread 1/2"thread

DC50G Series(Three-phase)

Product Appearance 

图片关键词

Specifications

NO.

Item

Specs

1

Dimension and weight

99.4mmx92.5mmx69.6mm;480g

2

External diameter of outlet

1/2” thread(M20)

3

External diameter of inlet

1/2” thread(M20)

4

Driving mechanism

Brush-less, magnetic isolated design

5

Material of pump shell

ABS,PES/SPS/PPS/PA66+30%GF (Optional)

6

Condition of use

Can continuously work, submersible or land use (not self-priming)

7

Suitable medium

Water, oil, or normal acid/ alkaline liquids

8

Max working temperature

60℃(for T sub-series) or 100℃(for S/A sub-series)

9

Power consumption

2.5W~48W(for T sub-series) or 2.5W~86.4W(for S/A sub-series)

10

Rated voltage

12Vdc or 24Vdc

11

Working voltage range

5Vdc ~ 14Vdc or 5Vdc ~ 26Vdc

12

Max load current

2.0A (for T sub-series) or 4.5A(for S/A sub-series)

13

Max horizontal flow rate

32L/MIN(for T sub-series) or 40L/MIN(for S/A sub-series)

14

Max static lift

4M(for T sub-series) or 8M(for S/A sub-series)                                     

15

Noise class

<40dB

16

Waterproof class

IP68(suitable for submersible installation)

17

Life span

>30,000hrsIP68(suitable for submersible installation)

18

Power supply

Suitable solar panel, batteries, adapter or other power source

19

Protection function

dry-run protection, lock protection(customized function)

20

Power regulation function

Speed adjustable by PWM signal, 0~5V analog signal or potentiometer

22

Feature

small size with high efficiency,maintenance-free

Use ceramics shaft and carbon fiber sleeve

Completely water proof (IP68)

Brush-less dc control without pollution, long life span

OEM and ODM service accept

Offer Pump related control system design

Electrical parameters (only for reference)

Model No.

Voltage

Max load current

Max static lift

Max flow rate

Power consumption

V(dc)

A

M

L/H

w

DC50G-1230T

12

2.0

3.0

1680

24

DC50G-1230S

DC50G-1230A

DC50G-1260S

12

4.5

6.0

2100

54

DC50G-1260A

DC50G-2440T

24

2.0

4.0

1920

48

DC50G-2440S

DC50G-2440A

DC50G-2480S

24

3.60

8.0

2400

86.4

DC50G-2480A

     NOTE

l  Information including continuous working time, working temperature and medium is required to be confirmed by professionals; pump cannot work with high temperature or corrosive fluids.

l  When pump is connected into circulation system, load current will be reduced to 70~85% of Max working current (opening outlet current).

l  Head means the Max vertical lifting height of water, the flow is 0L/MIN@max head.

The max flow rate means flow rate with no lifting height(horizontal flow rate)


Flow rate-lift Curve

图片关键词


Dimensions of pump

图片关键词

 

Outlook detail

图片关键词


在线预定

Telephone
Product list
Mall