BLDC Pump DC40C

Product information:

  • Voltage (DC): 24V
  • Current range: 0.15~1.2A
  • Max lift: 14L/MIN
  • Max flow: 15L/MIN
  • Inlet/ Outlet Dimension: 1/2

DC40C Series (Two-phase)

Product Appearance

图片关键词


 Specifications

NO.

Item

Specs

1

Dimension and weight

88.5mmx81.5mmx43.8mm; 235g

2

Installation dimension

88.5mmx81.5mmx56mm;

3

External diameter of outlet

1/2’’ threadedM20mm

4

External diameter of inlet

1/2’’ threadedM20mm

5

Driving mechanism

Brush-less, magnetic separation

6

Material of pump shell

ABS,PES/SPS/PPS/PA66+30%GF (Optional)

7

Condition of use

Can continuously work, submersible or land use (not self-priming)

8

Suitable medium

Water, oil, or normal acid/ alkaline liquids

(Test needed for special liquid)

9

Max working temperature

60

10

Power consumption

2.5W~28.8W

11

Rated voltage

12Vdc or 24Vdc

12

Working voltage range

5Vdc ~ 12Vdc or 5Vdc ~ 24Vdc

13

Max load current

1.2A

14

Max horizontal flow rate

15L/MIN

15

Max static lift

6M

16

Noise class

<40dB

17

Waterproof class

IP68(suitable for submersible installation)

18

Life span

Can be more than 30,000hrs

19

Power supply

Suitable for solar panel, batteries, adapter or other power module

20

Protection function

Water protection, dry-run protection, stall protection, stuck protection

(functions are optional for customization)

21

Power regulation function

Speed can adjustable by PWM signal, 0~5V analog signal or potentiometer (customized function)

22

Feature

l  small size with high efficiency,maintenance-free

l  Use ceramics shaft and carbon fiber sleeve

l  Completely water proof (IP68)

l  Brush-less dc control without pollution, long life span

l  OEM and ODM service accept

l  Offer Pump related control system design

Electrical parameters (only for reference)

Model No.

Voltage

Max load current

Max static lift

Max flow rate

Power consumption

V(dc)

A

M

L/H

w

DC40C-1230

12

0.90

3.0

620

10.8

DC40C-1240

12

1.2

4.0

720

14.4

DC40C-1850

18

1.20

5.0

780

21.6

DC40C-2450

24

0.90

5.0

780

21.6

DC40C-2460

24

1.20

6.0

900

28.8

NOTE

l  Information including continuous working time, working temperature and medium is required to be Confirmed by professionals; pump cannot work with high temperature or corrosive fluids.

l  When pump is connected into circulation system, load current will be reduced to 70~85% of Max working current (opening outlet current).

l  Head means the Max vertical lifting height of water, the flow is 0L/MIN@max head.

l  The max flow rate means flow rate with no lifting height(horizontal flow rate)


Flow rate-lift Curve

图片关键词

Dimensions of pump



图片关键词



Outlook detail

图片关键词


在线预定

Telephone
Product list
Mall