BLDC Pump DC30A

Product information:

  • Voltage (DC): 12V
  • Current range: 0.1~0.35A
  • Max lift: 3m
  • Max flow: 4L/MIN
  • Inlet/ Outlet Dimension: 8mm/8mm

DC30A Series(Two-phase)

Product Appearance

图片关键词

Specifications

NO.

Items

Specs

1

Dimension and weight

51mmx34mmx42.7mm; 50g

2

External diameter of outlet

8mm

3

External diameter of inlet

8mm

4

Driving mechanism

Brush-less, magnetic separation

5

Material of pump shell

ABS,PES/SPS/PPS/PA66+30%GF (Optional)

6

Condition of use

Can continuously work, submersible or land use (not self-priming)

7

Suitable medium

Water, oil, or normal acid/ alkaline liquids

(Test needed for special liquid)

8

Max working temperature

60

9

Power consumption

0.55W~4.2W(can be customized within this range)

10

Rated voltage

12Vdc

11

Working voltage range

5Vdc ~ 12Vdc

12

Max load current

0.35A @12Vdc

13

Max horizontal flow rate

4L/MIN   

14

Max static lift

3M                                           

15

Noise class

<40dB

16

Waterproof class

IP68(suitable for submersible installation)

17

Life span

More than 30,000hrs

18

Power supply

Suitable for solar panel, batteries, adapter or other power module

19

Protection function

Water protection, dry-run protection, stall protection, stuck protection

(functions are optional for customization)

20

Pump Feature

1.Small size with high efficiency, low noise and long life span.
2.Failure rate less than 0.5%.

3.Brush-less control without pollution.

4. control circuits are completely sealed by epoxy resin and isolated with rotor, no leaking.

Parameters (only for reference)

 

Model No.

Voltage

Max load current

Max flow rate

Max static head

Power consumption

Vdc

A

L/H

M

w

DC30A-0406

4.5

0.10

100

0.6

0.45

DC30A-0507

5

0.11

110

0.7

0.55

DC30A-0609

6

0.11

120

0.9

0.66

DC30A-0712

7

0.13

160

1.2

0.91

DC30A-0913

9

0.14

170

1.3

1.26

DC30A-1215

12

0.18

200

1.5

2.16

DC30A-1219

12

0.22

210

1.9

2.64

DC30A-1223

12

0.23

220

2.3

2.76

DC30A-1225

12

0.26

230

2.5

3.12

DC30A-1227

12

0.29

235

2.7

3.48

DC30A-1230

12

0.35

240

3.0

4.20

NOTE

l  Information including continuous working time, working temperature and medium is required to be confirmed by professionals; pump cannot work with high temperature or corrosive fluids.

l  When pump is connected into circulation system, load current will be reduced to 70~85% of Max working current (opening outlet current).

l  Head means the Max vertical lifting height of water.

l  The max flow rate means flow rate with no lifting height(horizontal flow rate)

Flow rate-Head Curve

图片关键词

Dimensions of pump

图片关键词



在线预定

Telephone
Product list
Mall